Ariston

Alteas ONE heat pumps and Genus boilers with Modbus TCP KNX integration

Ariston (Fabriano, Italy, founded 1930) manufactures gas boilers, heat pumps, and DHW heaters — dominant in Italian, Romanian, and Eastern European residential markets. The Ariston NET module adds Modbus TCP for KNX integration.

Role in our panels

How we use Ariston

Ariston's residential heat pump range centres on the Alteas ONE+ series (6, 8, 11, and 12 kW monobloc ASHP with integrated hydronic module). The Alteas ONE+ includes an integrated buffer tank, circulator pump, expansion vessel, and safety valve — simplifying installation compared to split-system heat pumps. The Genus ONE condensing gas boiler (18-30 kW) is Ariston's flagship residential boiler for Eastern European markets where gas heating remains prevalent. Both the Alteas ONE+ and Genus ONE support the optional NET module accessory for remote monitoring and Modbus TCP communication. The Ariston NET module (DIN rail, connects via Ariston proprietary BUS to the heat pump or boiler PCB) provides Modbus TCP on port 502 with default unit ID 1. The register map is documented in the Ariston NET module technical manual: Register 1 = flow temperature setpoint (°C × 10, read/write — write 550 for 55.0°C DHW setpoint), Register 5 = DHW setpoint (°C × 10), Register 100 = operating mode (0=off, 1=heating, 2=DHW only, 3=combined heating+DHW), Register 200 = fault code (0=no active fault, non-zero values reference Ariston fault code list). The Intesis IN701KNX gateway maps these registers to KNX group addresses: GA 8/0/0 flow temperature setpoint as DPT 9.001 (2-byte float), GA 8/0/1 operating mode as DPT 5.001, GA 8/0/4 fault as DPT 1.005. SG Ready integration for the Alteas ONE+ provides a simpler alternative to Modbus TCP when full register access is not required. The Alteas ONE+ control PCB has S1 and S2 terminals (SG Ready standard: two potential-free contacts). S1+S2 both closed = State 4 (forced DHW charge at maximum — emergency override). S1 closed only = State 3 (increased DHW setpoint and heating enabled — solar surplus mode). S1 and S2 both open = State 2 (normal mode). S2 closed only = State 1 (blocked/delay mode for grid management). A KNX relay actuator (e.g. MDT AKD-0401.02) directly controls the SG Ready contacts from a KNX GA responding to PV surplus logic — no NET module required for SG Ready. Ariston is the dominant residential heating brand in Romania, where it holds approximately 35% market share in gas boilers, and is strong in Poland, Bulgaria, and the Czech Republic. PanelCraft KNX panels for Eastern European projects typically include Ariston Genus ONE or Alteas ONE+ integration with local Modbus TCP via the NET module, complemented by SG Ready relay for rapid surplus response. Italian projects often combine Ariston Alteas ONE+ with KNX floor heating zone control and solar PV.

Ariston Genus One boiler and Alteas ONE+ heat pump use Modbus TCP via the optional Ariston NET module (DIN rail, connects via Ariston proprietary bus). NET module Modbus TCP port 502. Register map: Reg 1 = flow temperature setpoint (°C × 10, read/write), Reg 5 = DHW setpoint (°C × 10), Reg 100 = operating mode (0=off/1=heating/2=DHW/3=combined), Reg 200 = fault code (0=no fault). Intesis IN701KNX maps registers to KNX GAs: GA 8/0/0 setpoint DPT 9.001, GA 8/0/1 mode DPT 5.001, GA 8/0/4 fault DPT 1.005. Alteas ONE+ also has SG Ready S1/S2 terminals for PV surplus relay control.

Used in these project types

Italian residential new build — Alteas ONE+ 12 kW with KNX floor heating zone actuators and PV surplus SG Ready relay
Romanian apartment buildings — Genus One 24 kW with NET module Modbus TCP for KNX energy monitoring and setpoint scheduling
Polish residential — Alteas ONE+ ASHP replacing gas boiler, KNX integration for occupancy-based heating control
South European hotel heating — Ariston thermal plant with KNX room control and centralised energy management
Eastern European renovation projects — Ariston Genus One boiler + KNX thermostat via Modbus TCP gateway replacing old on/off controls

Ariston products

Key components we install

ARI-ALTEAS12Heat Pump

Alteas ONE+ 12

12 kW ASHP (air-source heat pump) monobloc with integrated hydronic module (buffer tank, circulator, expansion vessel). SG Ready S1/S2 terminals on PCB for PV surplus relay control — no NET module required for SG Ready. NET module accessory for Modbus TCP full parameter access. SCOP 4.0+ (A7/W35). R32 refrigerant. Single power connection (400V 3-phase). Compatible with KNX floor heating zone actuators for room-by-room temperature control.

ARI-GENUS24Boiler

Genus One 24

24 kW condensing gas boiler for CH and DHW (combi or system). ErP A-rated. Modulating burner 20-100%. NET module accessory for Modbus TCP (Register 1 CH setpoint, Register 5 DHW setpoint, Register 100 mode). Integrated OpenTherm interface (alternative to Modbus for basic setpoint control via OpenTherm gateway). Common in Romania, Poland, and Italy for residential new build and renovation. Compatible with Ariston Sensys Net room thermostat.

ARI-LYDOSDHW HP

Lydos Hybrid

Heat pump water heater 80L, ASHP mode COP 3.2, backup electrical resistance 1.8 kW. Wall-mounted, R134a. NET module compatible for Modbus TCP DHW setpoint control. SG Ready contacts built-in (S1/S2). Used in Italy and Southern Europe for solar surplus DHW heating — KNX relay actuator switches SG Ready State 3 (increased setpoint) when PV export exceeds 1.5 kW. 80L tank covers 2-4 person household DHW demand.

ARI-NETInterface

NET Module

Modbus TCP bus module for Ariston Genus ONE and Alteas ONE+ (optional accessory, sold separately). DIN rail mount (2 modules). Connects via Ariston proprietary BUS connector on boiler/HP PCB. LAN RJ45 port, Modbus TCP port 502, unit ID 1 (default). Register map in NET module technical manual. Requires certified Ariston installer for fitting. Also provides Ariston remote monitoring via Ariston cloud (separate from Modbus TCP local interface).

ARI-SENSYSThermostat

Sensys Net

Connected room thermostat with Modbus and OpenTherm interface. Wall-mount, 3.5-inch colour display. Communicates with Genus ONE boiler via Ariston bus. Modbus RTU RS485 option for integration with Modbus-based energy management systems. Not a KNX device natively — for KNX room temperature integration, use IN701KNX gateway reading boiler Modbus or route temperature via Ariston NET module registers.

Ariston FAQ

Is the Ariston NET module included with Alteas ONE+?

No — it is an optional accessory (ARI-NET) purchased separately and installed by a certified engineer. The Alteas ONE+ is delivered with SG Ready S1/S2 terminals accessible on the PCB — these work without the NET module for PV surplus relay control. The NET module is required only when full Modbus TCP register access (setpoint read/write, mode control, fault reading) is needed for KNX or energy management integration.

What is the Modbus TCP port for Ariston NET?

Port 502, unit ID 1 (default). These are standard defaults matching most Modbus TCP devices. If port 502 is in use on the network, the NET module Modbus TCP port can be changed in the Ariston NET module web interface (accessed via browser at the module's IP address). Unit ID cannot be changed from the default of 1 in current firmware — relevant only if two NET modules are on the same IP (not applicable with TCP).

Can Ariston Alteas ONE+ heat pump use SG Ready without the NET module?

Yes — SG Ready S1/S2 terminals on the HP control PCB accept relay contacts directly from KNX relay actuator without NET module. Wire KNX relay actuator output (volt-free contact) to Alteas ONE+ S1 terminal; S2 can be wired for State 4 (emergency charge) if required. Configure KNX logic: when PV export GA exceeds 2 kW threshold → send ON to relay actuator GA → S1 contact closes → SG Ready State 3 (increased setpoint). This is the recommended approach for PV surplus integration when Modbus TCP parameter access is not needed.