Canada · Est. 1995

Distech Controls

ECLYPSE BACnet controllers with native KNX module for room control without middleware

Distech Controls (Brossard, Quebec, Canada, founded 1995, acquired by Acuity Brands 2015) makes ECLYPSE series BACnet/IP DDC controllers used in hospitals, universities, and commercial buildings. Native KNX module eliminates BACnet/KNX gateway complexity.

Role in our panels

How we use Distech Controls

The ECLYPSE Connected Room Controller (CRC) is a DIN-rail BACnet/IP direct digital controller with 10 universal analog inputs, 4 analog outputs (0-10V), and 6 digital outputs (relay). The CRC is designed for room-level HVAC control: VAV box control, fan coil unit (FCU) management, and room temperature regulation. The ECLYPSE Configurator web interface (embedded HTTP server) provides point configuration, control loop tuning, and BACnet object browsing without additional software. The DTE-ECLYPSE-KNX module adds native KNXnet/IP connectivity to the ECLYPSE CRC. The ETS6 application for DTE-ECLYPSE-KNX is downloaded from distech-controls.com/resources and imported into the ETS6 project. The application automatically creates KNX group objects for each BACnet data point tagged for KNX export in ECLYPSE Configurator. Analog Input/Output data points map to DPT 9.001 (temperature, humidity, 2-byte float) or DPT 5.001 (percentage 0-100%). Binary Values map to DPT 1.001 (on/off) or DPT 1.005 (alarm). The physical address is set in ETS6 in the usual manner; the KNX interface mode (KNXnet/IP tunnelling via IP router) is configured in ECLYPSE Configurator. Bidirectional BACnet/KNX mapping is the key advantage of the ECLYPSE native module approach: a KNX room thermostat sends measured temperature (DPT 9.001) to a KNX GA, which the ECLYPSE module writes to a BACnet Analog Input — the ECLYPSE VAV control loop uses this measured value directly, replacing or overriding the local ECLYPSE sensor. The ECLYPSE then writes the calculated valve position (0-100%) to a BACnet Analog Output, which maps back to a KNX GA controlling a KNX actuator driving the physical valve. This full bidirectional loop is achievable within a single ECLYPSE KNX module — no third-party gateway in the data path. For multi-controller plants (hospital ward with 40+ rooms, university building), the EC-BOS-9 BACnet Object Server provides a supervisory layer: it aggregates all ECLYPSE controllers on the BACnet/IP network and provides alarm management, trend logging, and setpoint scheduling. For KNX-BACnet integration at the supervisory level (rather than room level), a LOYTEC LBRIDGE or similar BACnet/KNX gateway between EC-BOS and the KNX building backbone is the recommended architecture — leaving the ECLYPSE CRC + DTE-ECLYPSE-KNX module for room-level bidirectional control.

ECLYPSE room controller with DTE-ECLYPSE-KNX module: ETS6 application download from distech-controls.com/resources. Application provides group objects for each configured BACnet data point: Analog Input/Output → DPT 9.001 or DPT 5.001, Binary Value → DPT 1.001. In ECLYPSE Configurator: select 'KNX Integration', set KNX physical address, configure KNX interface (KNXnet/IP tunnelling to IP router). Group objects auto-created for all BACnet objects tagged for KNX. Bidirectional: ECLYPSE reads KNX room thermostat temperature → overrides BACnet Analog Input → ECLYPSE VAV control loop uses measured temperature.

Used in these project types

Hospitals and healthcare — ECLYPSE CRC for patient room temperature control with KNX lighting integration via DTE-ECLYPSE-KNX
Universities and campuses — EC-BOS-9 multi-building supervisor with ECLYPSE room controllers and KNX blinds/lighting at room level
Commercial offices — ECLYPSE VAV control with KNX pushbutton temperature override at each workstation
Government buildings — Distech Controls specified in public sector tenders requiring BACnet/IP compliance with KNX room integration
International hotel chains — ECLYPSE room controller for HVAC, DTE-ECLYPSE-KNX for KNX in-room control (lighting, blinds, welcome scene)

Distech Controls products

Key components we install

DTC-CRCRoom Controller

ECLYPSE CRC

BACnet/IP DDC room controller with 10 universal analog inputs (0-10V/NTC/PT1000/Dry Contact), 4 analog outputs (0-10V), 6 digital outputs (relay 24VAC). DIN rail 8 modules. Embedded ECLYPSE Configurator HTTP server for commissioning. EIKON and EC-gfxProgram compatible for control logic. BACnet/IP client and server. Connects to DTE-ECLYPSE-KNX module for native KNX integration. Used for VAV control, FCU control, and room temperature regulation in commercial buildings.

DTC-KNXKNX Module

DTE-ECLYPSE-KNX

Native ETS6 KNX integration module for ECLYPSE room controllers. Plugs into ECLYPSE CRC expansion slot. Provides KNXnet/IP tunnelling interface — connects to KNX IP router on building LAN. ETS6 application downloaded from Distech portal. Up to 120 KNX group objects per module, auto-generated from BACnet data points tagged in ECLYPSE Configurator. Bidirectional: KNX reads ECLYPSE sensor values; KNX writes to ECLYPSE setpoints. No third-party gateway required.

DTC-EBOS9BACnet Server

EC-BOS-9

256-point BACnet/IP building operations server. Supervisory controller aggregating ECLYPSE CRC and other BACnet/IP devices. Trend log storage (up to 100 trends, 10000 samples each). Alarm management with email notification. Schedule and calendar objects for setpoint programs. EC-Net 5 integration for enterprise BMS. Rack or DIN rail mount. Used in hospitals and universities as ward/building-level supervisor above room-level ECLYPSE CRCs.

DTC-MPARAHU Controller

MACH-ProAir

DDC controller for air handling units. BACnet/IP. Multiple AI/AO/DI/DO points for AHU sequence: supply/return temperature, mixed air temperature, filter differential pressure, economiser damper, heating/cooling coil valves, fan speed (0-10V to VFD). Programmed in EC-gfxProgram. Integrates with ECLYPSE room controllers via BACnet for demand-controlled ventilation. KNX integration via building backbone BACnet/KNX gateway or separate Modbus TCP path.

DTC-ECNET5BMS Software

EC-Net 5

Open protocol BMS platform supporting BACnet/IP, BACnet MS/TP, Modbus, LonWorks, and KNX (via LOYTEC bridge). Web-based HTML5 client. Trend, alarm, and schedule management for multi-site portfolios. OPC UA server for SCADA integration. Customisable dashboard graphics. Used as enterprise BMS above EC-BOS-9 supervisory controllers in hospital campuses and university multi-building estates.

Distech Controls FAQ

Does ECLYPSE require a separate KNX/BACnet gateway?

No — the DTE-ECLYPSE-KNX module provides native KNX integration without a third-party gateway. The module plugs into the ECLYPSE CRC, provides a KNXnet/IP tunnelling interface, and is programmed via ETS6 using the Distech ETS6 application downloaded from distech-controls.com. This eliminates the cost, complexity, and additional failure point of a separate BACnet/KNX gateway device.

Can I programme ECLYPSE from ETS6?

No — ETS6 is used to configure KNX group addresses only. ECLYPSE control logic (VAV sequence, PI loops, setpoint schedules) is programmed in Distech EIKON (graphical, browser-based, similar to Loxone Config) or EC-gfxProgram (ladder logic). The DTE-ECLYPSE-KNX ETS6 application only configures which BACnet data points appear as KNX group objects and which KNX group addresses they link to.

How many KNX group objects can ECLYPSE support?

Up to 120 KNX group objects per ECLYPSE module, corresponding to configured BACnet data points. This covers a typical hotel room (temperature setpoint, measured temperature, valve position, fan speed, presence, window contact, lighting scenes = approximately 15-20 GOs) with significant headroom. For larger rooms or suites requiring more GOs, multiple ECLYPSE CRC units with individual DTE-ECLYPSE-KNX modules can be used.

Need a panel with Distech Controls components?

We select, procure, assemble and certify. Free initial consultation.

Request consultation →