EV Charging & Smart Load Management
KNX integration with EV chargers for PV self-consumption and dynamic load management — OCPP gateway setup, charge current control, EVCC self-consumption coordination, and multi-charger load balancing.
Easee Home and Wallbox Pulsar KNX Integration via OCPP 1.6J Gateway
Integrating Easee Home and Wallbox Pulsar Plus EV chargers with KNX — OCPP 1.6J central system setup, charge current GA (DPT 5.001), charger status GA, RFID authorization from KNX, KNX-to-OCPP gateway configuration (IP-Symcon, Home Assistant), and commissioning test with ETS6 Group Monitor.
EVCC Self-Consumption EV Charging with KNX: Fronius Modbus and SG Ready Coordination
Configuring EVCC (Electric Vehicle Charge Controller) for solar self-consumption EV charging — EVCC Fronius/SMA Modbus integration, EVCC KNX plugin for surplus export to charger, min/fast/PV mode switching from KNX pushbutton, SG Ready heat pump coordination, and EVCC dashboard with KNX status GAs.
Dynamic Load Management for Multiple EV Chargers with KNX: Demand Monitoring and Current Distribution
KNX dynamic load management for multi-charger EV installations — ABB B24 Modbus energy meter as demand sensor, KNX logic for current distribution between chargers, overload prevention with load shedding priority, and Easee Equalizer integration for automatic distribution.
Need an EV charging panel with KNX dynamic load management built to spec?
We design and manufacture low-voltage panels with OCPP integration, KNX dynamic load management, and multi-charger current distribution — delivered tested and commissioned to your site.
Request a quote →