Larnitech DIN Modules in the Panel: Assembly Practice

Larnitech runs on its own CAN bus, not KNX, so the panel layout follows CAN bus discipline: gateway positioned for bus access, modules grouped by function, CAN wiring kept clear of the 230V circuits around it.

Independent engineering assessmentPanel assembly to IEC 61439EU-wide project support
CAN-BUS
CAN
CAN modulis
Panel layout, step by step

Panel layout, step by step

01

Position the Main Gateway for bus access

The Main Gateway carries two CAN bus connections, one at each end of the line. It goes where both ends of the linear CAN run are reachable, with termination fitted at each end as any CAN network requires.

02

Group modules by function and floor

Actuator, extension and dimmer modules are arranged by the circuits they serve, not by delivery order. Heating and LED controllers sit near their load circuits, and the leak-protection module goes near the wet-area wiring it watches.

03

Keep CAN wiring clear of 230V

The CAN High/CAN Low pair is routed separately from the 230V power wiring inside the enclosure, with WAGO-type connectors at every module tap for a clean, serviceable bus connection.

04

Label every module and channel

Each module and channel is labeled as it's wired in, so the next service call starts from the panel itself, not from guesswork.

What layout discipline buys you

What layout discipline buys you

2

CAN connections, both ends terminated

The Main Gateway's two bus connections anchor Larnitech's linear CAN topology, terminated at both ends — the rule every CAN network runs on, applied inside the panel.

Gateway at the line's reach

Placed so both ends of the CAN run are within reach for termination, not tucked where a future service visit needs the panel half-stripped.

Function-first grouping

Actuator, extension and dimmer modules sit with the circuits they drive rather than sorted by module type.

Load-adjacent controllers

The heating controller and LED controller are placed near the circuits they switch, shortening runs and keeping the wiring readable.

Leak protection near the risk

The leak-protection module sits close to the wet-area wiring it monitors, not on the far side of the enclosure.

WAGO taps, every module

CAN High/CAN Low connects at each module through WAGO-type connectors, kept apart from the 230V wiring in the same enclosure.

Options

What we hand over with the panel

Documentation delivered at the end of every Larnitech panel build.

  • Module map: gateway, actuator/extension/dimmer, heating/LED controller and leak-protection positions
  • Channel assignment sheet, module by module
  • CAN bus wiring record — WAGO tap points, termination at both bus ends
  • App configuration snapshot at handover
  • Labeled DIN rail modules and channels, ready for service
FAQ

Frequently asked questions

Where does the Larnitech Main Gateway go in the panel?

Where both ends of the linear CAN bus run are reachable. The Main Gateway has two CAN bus connections, one at each end of the line, and both ends need termination — so gateway placement is driven by bus access, not just free DIN rail space.

Why keep CAN High/CAN Low separate from the 230V wiring?

The CAN pair is a low-voltage signal bus running alongside mains wiring in the same enclosure. Routing it separately from the 230V circuits keeps the bus readable for service and avoids interference risk between the two.

Why use WAGO connectors at every Larnitech module tap?

WAGO-type connectors give a consistent, toolless bus connection at each module, so adding or swapping a module later doesn't mean re-terminating wire by hand.

How should actuator, dimmer and extension modules be grouped in the panel?

By the function or floor they serve rather than by module type — heating and LED controllers near their load circuits, the leak-protection module near the wet-area wiring it monitors, actuators and dimmers grouped with the circuits they control.

Is a Larnitech panel built the same way as a KNX panel?

The enclosure discipline is the same — IEC 61439 practice, labeled circuits, documented handover. But Larnitech is its own CAN bus system, not KNX, and its modules aren't interoperability-certified with KNX devices the way different manufacturers' KNX actuators and sensors are certified with each other.

Planning a Larnitech panel build?

Our engineers assemble Larnitech panels to IEC 61439 practice across the EU — talk to us about module layout, bus wiring or your handover documentation.

Contact our engineers